Triton MPR6-03 patient monitor N-Electronics how to use guide

This is the Triton MPR6-03 (МПР6-03) multi-parameter patient monitor, manufactured by N-Electronics (Н-ЭЛЕКТРОНИКС) - a Russian medical device company. It is used in ICUs, operation theaters, and pediatric wards to continuously monitor multiple vital signs simultaneously.

What This Monitor Tracks

Based on what's visible on your screen:
ParameterWhat It Measures
ECGHeart electrical activity (4-lead, 25mm/s sweep)
ST segmentCardiac ischemia detection
HR (Heart Rate)Beats per minute (limits: 75-160 bpm)
SpO2Blood oxygen saturation (pulse oximetry)
NIBPNon-invasive blood pressure
Temperature (T°C)Body temperature (39.0°C showing)
BP reading126/70 mmHg (101 MAP) visible
dPWTPulse wave transit time - 27/32 values visible
HRV / MO / AMO / PIHeart rate variability indices
CAPNOCapnography (end-tidal CO2 - button visible)
ModeSet to Pediatric (Pediat.) - currently monitoring a child

How to Use It - Step by Step

1. Power On

  • Press the round green power button (bottom-left of the device bezel).
  • The monitor runs on mains power (СЕТЬ) or battery (БАТ) - both indicators are shown at the bottom.

2. Connect Patient Sensors

Attach the appropriate sensors in this order:
  • ECG leads - 4-lead cable to chest/limb electrodes (currently configured for 4 leads)
  • SpO2 probe - finger clip or wrap probe to the patient's finger
  • NIBP cuff - wrap around upper arm; press the NIBP button on the front panel to start a measurement
  • Temperature probe - skin or rectal probe
  • Capnography - if needed, via the CAPNO port (button visible on front panel)

3. Set Patient Category

  • The monitor is currently in Pediatric mode (visible as "Pediat." at the bottom right of the screen). This adjusts alarm thresholds for a child.
  • For an adult, navigate the menu to change the patient category.

4. Set Alarm Limits

  • Each parameter has upper and lower alarm limits (e.g., HR: 75-160 bpm; SpO2 high/low shown by yellow bars on the right).
  • Access alarm settings through the on-screen menu using the rotary knob (right side of the monitor) or the function buttons (teal buttons on the front panel).

5. Navigate the Screen

  • Rotary knob (right side) - scroll through menus and confirm selections.
  • 6 teal function buttons on the front panel correspond to on-screen labels. The visible ones include CAPNO, NIBP, FREEZE (freeze waveform), and a speaker/alarm icon.
  • The FREEZE button pauses the waveform display for closer inspection.

6. NIBP (Blood Pressure) Measurement

  • Press the NIBP button on the front panel to start an automatic cuff inflation cycle.
  • The current reading shows 126/70 (101) - systolic/diastolic (mean).
  • You can set automatic interval measurements through the menu.

7. Address the "SENSOR RESET!" Alert

  • The screen currently shows a "SENSOR RESET!" warning in the middle. This typically means a sensor (likely SpO2 or another probe) has been disconnected or needs to be reattached. Reconnect the relevant sensor and the alert should clear.

8. ECG Waveform Interpretation

  • The top channel shows the ECG trace at 25mm/s, 1mV scale.
  • ST segment changes are automatically calculated.
  • Lead selection and gain can be adjusted through the on-screen ECG menu.

Key Front Panel Controls

ControlFunction
Green round buttonPower ON/OFF
Rotary knob (right)Navigate menus / confirm
Teal buttons (row)Context-sensitive screen functions
CAPNO buttonCapnography settings
NIBP buttonStart/stop BP measurement
FREEZE buttonFreeze waveform on screen

Important Notes

  • The date/time shows 06:26:28 / 12/04/03 (bottom-left) - verify the clock is correctly set.
  • The ESU indicator (top right area) means electrosurgical unit interference protection is active - useful during surgery.
  • A yellow alarm triangle is visible at the top, indicating a non-critical alarm is active. Check which parameter triggered it.
  • Since the mode is Pediatric, ensure the correct age/weight category is selected in the patient profile for accurate alarm thresholds.
For the official user manual, contact N-Electronics (Н-ЭЛЕКТРОНИКС) or search for the МПР6-03 руководство по эксплуатации (Russian-language operator manual), as this is a Russian-manufactured device.